Due to tons of abuse, we now require that you request user access by sending us your Login, Name, Email Address, Phone Number, and Profession by submitting that info HERE.  I'll review your request and try to get back to you within the week.  You can't imagine how many folk want to trash forums with bogas advertising. 

Also, please help us gain enough Facebook "Likes" to have a custom Facebook URL!  

--Gary Lieberman

DME Separate Sides

7 replies [Last post]
Matt Saplin
User offline. Last seen 2 years 41 weeks ago. Offline
Joined: 29 Oct 2005

Having trouble with an effect that I built that uses the DME's ability to use separate sides. For all keyframes, I have 'separate sides' enabled on page 4162 ... the trouble is that the effect doesn't recall the back side inputs, and I need to change those crosspoints manually and then modify the effect each time I recall it. Once the effect is in register space and I've made my changes, everything is OK. If I save that effect and recall it later, the back side recalls with the same inputs as the front side.

Any thoughts or ideas? Using an MVS-8000G with MVE-9000.

Thanks,
Matt

wink hackman
User offline. Last seen 12 years 48 weeks ago. Offline
Joined: 20 Oct 2005
Re init status: unlike setup data, which is copied directly from volatile memory to disk when you save a setup in 7112, init status data is copied from flash to disk (and back - only loaded to volatile memory on reboot). So you have to do an init status define in 7314 before you save the modified init status data to disk.
Bill D
User offline. Last seen 10 years 32 weeks ago. Offline
Joined: 18 Aug 2005
[quote="fbass"]Just tried it. Setting DME2 frame's INITSTAT to XPT HOLD off works as you expect. Recalling the CWB turns XPT HOLD "off" on the ext DME's.[/quote] Fred, thanks will try again monday, maybe I never saved my 'initial satuts to HD after I did it.
fbass
User offline. Last seen 7 years 20 weeks ago. Offline
Joined: 6 May 2007
Just tried it. Setting DME2 frame's INITSTAT to XPT HOLD off works as you expect. Recalling the CWB turns XPT HOLD "off" on the ext DME's.
Bill D
User offline. Last seen 10 years 32 weeks ago. Offline
Joined: 18 Aug 2005
Anyone know why when I use the clear work buffer on DME channels to build a new effect I have to go in and turn off the x-point hold (so that the effect calls up the source I want). I have tried to set this with the initial status or whichever menu that sets clear working buffer, so that it is off but it does not work
Matt Saplin
User offline. Last seen 2 years 41 weeks ago. Offline
Joined: 29 Oct 2005
Just incase anyone else needs it, it's menu 6113.15 (Path, DME Effect, Xpt Hold). Since I needed an ME as part of this effect, I also did a Xpt Hold on the keyer where the DME channels were assigned. Thanks again for the help, Phil... Matt
Matt Saplin
User offline. Last seen 2 years 41 weeks ago. Offline
Joined: 29 Oct 2005
Thank you, Phil ... I feel so DUMB! Why did I not even think of looking there?? :-) Much appreciated, Matt
P Moss
User offline. Last seen 14 years 5 weeks ago. Offline
Joined: 7 Oct 2006
Matt You need to turn xpoint hold off on the DME you are using. I think the menu is 6113.13 The default for this is xpoint hold on Regards Phil