Multi-Program 2 Delays
- Login to post comments
Hi,Wonder if anyone has information on the frame delays when using MP or MP2? Are there differences in timing between the main and sub outputs?Also, I tried to assign the main and subs of the same M/E on different banks of the same control panel, but was unable, wonder if there's a workaround or I got something wrong? (Eg. on a CCP-9000, I tried assigning from the top: ME/1 Main, M/E1 Sub, M/E 2 Main, P/P MainIs this possible?
- Login to post comments
I believe that in order to re-enter an M/E's output back into the same M/E, you have to turn on this functionality. To activate this, go to the ENG menu - I believe that it's under the SWITCHER sub-menu (7331), and look for the button that activates the MP II unlimited free re-entry.
This is a software function & you need one of the more recent software releases.
When using the Main or Sub sides of an M/E, there are no timing differences throught the switcher or outputs...except if you re-enter a sub side back into a main side: in this case there's a 1-line delay.
Bob Ennis