Hello Editsuite.com friends,

Due to tons of abuse, we now require that you request user access by sending us your Login, Name, Email Address, Phone Number, and Profession by submitting that info HERE.  I'll review your request and try to get back to you within the week.  You can't imagine how many folk want to trash forums with bogas advertising. 

Also, please help us gain enough Facebook "Likes" to have a custom Facebook URL!  

--Gary Lieberman

Kalypso PP Transition Fader problem

1 reply [Last post]
danversjflett
User offline. Last seen 14 years 25 weeks ago. Offline
Joined: 2 Mar 2007

Hi all,

We've got a 4ME Kalypso Classic running v14.0.2. Last night for some reason the PP transition fader developed a problem where a full movement of the fader would only cause a 50% mix. Looking at the ME>Transition menu it shows the fader at 0% in the upper position and in the fully lower position it shows the mix at somewhere between 50% and 60% - it's not consistent. The mixer will correctly do a full transition if the Auto Trans button is pressed, but will only do a partial wipe or mix or key transition if the manual fader is used.

Doing a calibration shows that the fader is reading the correct values for the full range of movement when compared to the faders on the other ME rows. So it seems to be a software or firmware issue in the panel.

I've done a calibration a few times trying the fader in different positions for the upper and lower calibration values, and the best I've been able to get is a 90% range of movement - not good enough to do a full transition. I've also tried loading other emems and I even did an NV Memory clear on the frame, but still no dice.

Any suggestions? The director/switcher suggested that we just set the "pattern limit" - but after looking through the menus I can't find how to do a pattern limit on purpose in the Kalypso.

Dan Flett
Broadcast Engineer
Global Television
Australia

danversjflett
User offline. Last seen 14 years 25 weeks ago. Offline
Joined: 2 Mar 2007
I found the problem - it was mechanical after all. One of the screws holding the arm to the rotary encoder was missing and the other was loose. It meant that the arm usually wasn't able to complete a full movement - no matter how I tried to fool the calibration, the arm did not reach the end-stop most of the time and so did not complete the transition. We replaced the arm with a spare (easier than I had thought thanks to the modular circuit boards), and now it works fine.